EM100 supports external keypad to connect to the network interface RJ45 nearby the control terminal block. See Figure 3-22. But if 2 keypads are used simultanously, the potentiometer on the keypad would be damaged.
Solution:
If the external keypad is used, please take off the keypad on the inverter.
The maximum torque of EM100-0R4~4R0 shall be within 1.2Nm. The wiring terminal wound be broken if the tightening torque is too big. Recommended screwdriver for tightening: PH0 cross screwdriver or cross screwdriver of industrial Grade 0# (The diameter of screwdrive shaft =3mm), or flathead screwdriver (The head width: 4.5~5.0mm).
-theme-font:minor-latin;color:black;mso-themecolor:text1''>In addition, please connect 1-phase 220V input power cable to L1 and L2. Otherwise, there is no power supply, and no display on the keypad. k;mso-themecolor:text1''>If the function code has to be edited, it shall be finished by function code address+register address 2000H.
In addition, please connect 1-phase 220V input power cable to L1 and L2. Otherwise, there is no power supply, and no display on the keypad..